Western Treatment Plant Carrier and Main Pipelines, Melbourne
Line features showing the indicative location of carrier and main sewer pipelines inside the Western Treatment Plant wastewater facility near Cocoroc and Point Wilson, Victoria. Each of the 1,377 pipe segments has its sewer name, pipe type, material, size, invert levels, length, grade and service status. Callers get the features per suburb as GeoJSON or near an address.
Endpoints
Western Treatment Plant Carrier and Main Pipelines, Melbourne (map)
/v1/suburbs/{suburb_name}/layers/western-treatment-plant-carrier-main-pipelines10¢ per call| Query parameter | Description |
|---|---|
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/suburbs/Cocoroc/layers/western-treatment-plant-carrier-main-pipelines' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
Western Treatment Plant Carrier and Main Pipelines, Melbourne nearby
/v1/properties/{gnaf_id}/layers/western-treatment-plant-carrier-main-pipelines/nearby10¢ per call| Query parameter | Description |
|---|---|
radius_m | Search radius in metres, 1 to 2000 (default 500). |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/properties/GAVIC720839032/layers/western-treatment-plant-carrier-main-pipelines/nearby' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
The Western Treatment Plant area on Melbourne's south-western coast, between about 144.49 and 144.67 longitude and -38.05 and -37.93 latitude. The example suburbs are Cocoroc and Point Wilson. The layer holds 1,377 line features. Its time reference starts on 2019-11-14, and it was last modified on 2025-06-25. Current to 2025-06-25; refreshed As published. No fixed update schedule is stated. The layer is revised when completed projects and certified survey plans supply new information..
What it is
A line layer of carrier, main, recirculation and cross-connection pipelines within the Western Treatment Plant. Each feature is one pipe segment with identifiers, a pipe type description, the sewer it belongs to, and engineering attributes such as material, upstream and downstream invert levels, length, width, height and grade.
What it shows
It shows where wastewater pipes run across the plant site and what they are: main carrier, secondary carrier, main sewer or cross connection. It also records whether each segment is in or out of service and, for some segments, the construction date and as-constructed plan reference.
Why use it
Anyone planning works, surveys or development near the plant can check whether buried or surface pipe assets are likely to be present before they dig or build. Engineers and asset analysts can use the attributes to screen pipe sizes, materials and levels. It is for high-level awareness only and does not replace formal asset location checks.
How it is built
We take the pipeline line features and attributes as supplied and serve them as map features with attributes, grouped by suburb and searchable near an address. All 1,377 features fall inside a suburb. Many descriptive fields are blank for most segments, so records are uneven in detail.
Shortcomings
- Locations are indicative only. The data owner gives no guarantee of accuracy or completeness, so it is not a substitute for a formal asset search or on-site survey.
- Many attributes are mostly blank. Parallel line number is empty for 97% of rows, shape for 90%, construction date for 88% and the section number for 87%. The as-constructed plan number is empty for 89% of rows.
- Data quality varies by segment. Some geometry comes from design or digitised aerial photos rather than as-constructed survey, and the last-updated dates for many rows are from 2014.
- Some rows carry zero values for length, width, height or component keys, which look like placeholders rather than real measurements. Units for the invert levels and grade are not stated.
Fields
| Field | Unit | Description |
|---|---|---|
mxunitidAsset unit ID | Combined identifier of the pipe segment, usually formed from its start and end node IDs. | |
mxsiteidSite ID | Code for the site the asset belongs to; the example value is MWS. | |
compkeyComponent key | Numeric asset component key; 0 where none is recorded. | |
comptypeComponent type code | Numeric code for the component type; 0 where none is recorded. | |
unitidStart unit ID | Identifier of the node at the start of the pipe segment. | |
unitid2End unit ID | Identifier of the node at the end of the pipe segment. | |
parallel_line_nbrParallel line letter | Letter that separates parallel pipes along the same route; blank for most rows. | |
unittypePipe type code | Short code for the pipe type, such as MAIN, MAINC, RECIRC or RM. | |
unittype_descPipe type description | Plain description of the pipe type, such as main sewer, main carrier, secondary carrier or cross connection. | |
sewer_nameSewer name | Name of the sewer, lagoon or area the pipe serves, such as Paddock Section S or Delta West Area. | |
asset_idAsset ID | Short asset code for the sewer or section, such as LSEC, OSEC or 85WA. | |
subareaSubarea code | Code for the sub-area of the plant, such as WTPS, WCAR, WSLG or WTPR. | |
shapePipe cross-section shape | Cross-section shape code, such as CIRC for circular; blank for most rows. | |
materialPipe material | Pipe material code, such as UPVC, HDPE, MSCL or RCP. | |
upstream_ilUpstream invert level | m | Invert level at the upstream end of the pipe; the unit is not stated, and metres is assumed. |
downstream_ilDownstream invert level | m | Invert level at the downstream end of the pipe; the unit is not stated, and metres is assumed. |
pipe_lengthPipe length | m | Length of the pipe segment; the unit is not stated, and metres is assumed. Values range from 0 to 6469.2. |
pipe_widthPipe width | mm | Pipe width or diameter; the unit is not stated, and millimetres is assumed. Values range from 0 to 4000. |
pipe_heightPipe height | mm | Pipe height; the unit is not stated, and millimetres is assumed. Values are 0 or up to 900. |
gradePipe grade | Slope of the pipe between its upstream and downstream ends, from about -0.37 to 0.52. | |
date_of_constructionConstruction date | Date the pipe was constructed; blank for 88% of rows. | |
epms_sec_noProject section number | Reference number of the project section that built the asset; blank for 87% of rows. | |
asconst_plan_noAs-constructed plan number | Reference number of the as-constructed drawing for the pipe; blank for 89% of rows. | |
sourceData source type | How the location was derived, such as design, as constructed, graphics or aerial photos. | |
method_of_captureCapture method | Method used to capture the geometry, such as digital, digital data or coordinates. | |
date_capturedDate captured | Date the geometry was captured; blank for 84% of rows. | |
date_last_updatedDate last updated | Date and time the record was last edited; many are from December 2014. | |
service_statusService status | Whether the pipe is in service (IN) or out of service (OUT). | |
commentsComments | Free-text notes on the pipe, such as its purpose or a direction check; blank for 98% of rows. |
Data source: Melbourne Water