Temperature and Humidity Sensor Readings, Geelong and Bellarine Region
Point readings of air temperature and relative humidity from a network of low-power weather sensors around Geelong, the Bellarine Peninsula and nearby areas in Victoria. Each record is one sensor reading with its location, device ID, temperature in degrees Celsius, humidity in per cent and battery voltage. Callers can fetch readings per suburb as GeoJSON or find sensors near an address.
Endpoints
Temperature and Humidity Sensor Readings, Geelong and Bellarine Region (map)
/v1/suburbs/{suburb_name}/layers/temperature-humidity-sensors-geelong-bellarine10¢ per callServed by /v1/suburbs/{suburb_name}/layers/{slug}, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/suburbs/Anakie/layers/temperature-humidity-sensors-geelong-bellarine' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
Temperature and Humidity Sensor Readings, Geelong and Bellarine Region nearby
/v1/properties/{gnaf_id}/layers/temperature-humidity-sensors-geelong-bellarine/nearby10¢ per callServed by /v1/properties/{gnaf_id}/layers/{slug}/nearby, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
radius_m | Search radius in metres, 1 to 2000 (default 500). |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/properties/GAVIC425028519/layers/temperature-humidity-sensors-geelong-bellarine/nearby' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
Geelong and the Bellarine Peninsula area of Victoria, within a bounding box of roughly longitude 144.27 to 144.71 and latitude -37.89 to -38.29. Example suburbs include Anakie, Armstrong Creek, Breamlea, Leopold, Moolap and Portarlington. Records start from 10 February 2025 and the dataset was last modified on 25 June 2025. It has 114,932 readings. Current to 2025-06-25; refreshed As published; no fixed update schedule is stated..
What it is
A layer of 114,932 point records, each a single reading from a fixed temperature and humidity sensor. Records carry the sensor's device ID, a place label, the measured temperature and humidity, battery voltage and the reporting interval. The sensors are used for local weather, site monitoring, wetland monitoring and bat habitat sites.
What it shows
It shows how air temperature and humidity vary between suburbs and sites over time, including hot spots and cooler or more humid pockets. Temperatures in the data range from 4.13 to 33.97 degrees Celsius and humidity from 29.64 to 99.96 per cent. Battery voltage (2.76 to 3.51) shows sensor health.
Why use it
Hyperlocal readings help with heat exposure assessment, comparing microclimates between suburbs, and checking conditions near a property or site. They can also support environmental monitoring and validate regional weather estimates. Analysts can use them alongside property and area data to look at liveability and climate risk.
How it is built
We load sensor readings as point features and attach them to the suburb they fall in. Every feature falls inside a suburb, and the API returns them per suburb as GeoJSON or as those near an address. The temperature and humidity fields duplicate the raw payload values. Readings are reported every 900 seconds (15 minutes). Coverage is limited to where sensors are installed.
Shortcomings
- Coverage is only suburbs and sites that have a sensor, so most places have no reading and sensors are not evenly spread.
- Readings are raw sensor outputs with no stated calibration or quality checking. Siting (shade, ground level, buildings) can bias values, so they may differ from standard weather station readings.
- The record period is short (from February 2025), so the data cannot support long-term climate trends or seasonal comparison over multiple years.
- The timestamp is stored as a numeric value that is not an obvious standard date, so check it before converting to dates. The temperature and humidity fields repeat the payload fields.
Fields
| Field | Unit | Description |
|---|---|---|
metadata_timeReading timestamp | Numeric time value for when the reading was recorded, stored as an integer and needing conversion before use as a date. | |
nameSensor location name | Street and suburb label for where the sensor is installed, for example a road name and suburb. | |
dev_idDevice ID | Unique identifier of the sensor that produced the reading. | |
payload_fields_tempPayload temperature | °C | Air temperature as reported in the sensor's raw payload, in degrees Celsius. |
payload_fields_humPayload humidity | % | Relative humidity as reported in the sensor's raw payload, in per cent. |
payload_fields_batteryBattery voltage | V | Battery voltage of the sensor at the time of the reading, useful for judging sensor health. |
payload_fields_periodReporting period | Interval at which the sensor reports, given as text such as 900 sec. | |
skip_record_flagSkip record flag | Boolean flag marking whether a record should be skipped; it is false for all records. | |
temperatureTemperature | °C | Air temperature of the reading in degrees Celsius, ranging from 4.13 to 33.97. |
humidityRelative humidity | % | Relative humidity of the reading in per cent, ranging from 29.64 to 99.96. |