Sewerage Mains – Bundaberg Region
Line map of sewer pipes (gravity, pressure, trunk and overflow mains) across the Bundaberg region. Each of the 12,185 pipe segments carries its diameter, depth, length, material, pipe class, asset type and the wastewater treatment plant catchment it serves. Callers can retrieve it per suburb as GeoJSON or for the area near an address.
Endpoints
Sewerage Mains – Bundaberg Region (map)
/v1/suburbs/{suburb_name}/layers/sewerage-mains-bundaberg-region10¢ per callServed by /v1/suburbs/{suburb_name}/layers/{slug}, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/suburbs/Bargara/layers/sewerage-mains-bundaberg-region' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
Sewerage Mains – Bundaberg Region nearby
/v1/properties/{gnaf_id}/layers/sewerage-mains-bundaberg-region/nearby10¢ per callServed by /v1/properties/{gnaf_id}/layers/{slug}/nearby, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
radius_m | Search radius in metres, 1 to 2000 (default 500). |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/properties/GAQLD156354922/layers/sewerage-mains-bundaberg-region/nearby' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
Bundaberg region in Queensland, including suburbs such as Alloway, Ashfield (Qld), Avenell Heights, Avoca (Qld), Branyan, Bundaberg Central, Bundaberg East, Bundaberg North, Bundaberg South and Bundaberg West. It holds 12,185 line features within bounds of roughly 151.85 to 152.58 E and -25.24 to -24.72 S. Records date from 6 August 2025. Current to 2026-06-27; refreshed As published; no regular update schedule is stated..
What it is
A line layer of sewerage mains. Each feature is one pipe segment with an asset identifier, a pipe type, physical attributes (diameter, depth, length, material, class) and the sewer service area and treatment plant catchment it belongs to.
What it shows
It shows where sewer pipes run, whether they are gravity, pressure, trunk, siphon or overflow mains, and how large and deep they are. It also shows which catchment, such as Rubyanna, Millbank or Thabeban, each segment drains to.
Why use it
Sewer location and capacity affect development feasibility, servicing costs, and the risk of building or digging near mains. Analysts can use it to check whether a property is near a sewer line and what size and type of pipe is present. It also helps with infrastructure planning and pre-dig checks.
How it is built
We load the pipe lines as supplied and attach them to suburbs. Suburb calls return features simplified to about 5 metres, while nearby-an-address calls return full detail. All features fall inside a suburb. Upstream and downstream values and pipe dimensions are as recorded, and we do not estimate missing values.
Shortcomings
- Pipe dimension and its unit are blank for about 94 to 96 percent of rows, so they cannot be used to size pipes. Use the pipe diameter field instead.
- Suburb calls simplify geometry to about 5 metres, so they are not suitable for precise location or survey work.
- Only sewer mains are included. House connections, manholes and pump stations are not part of this layer.
- Positions and depths are as recorded and are not a substitute for an on-site utility locate before digging.
Fields
| Field | Unit | Description |
|---|---|---|
complex_assPipe type category | Broad pipe type such as Pressure, Gravity or Gravity by size band (100mm, over 100mm). | |
complex_a_1Asset ID | Asset identifier for the sewer pipe, beginning with SM. | |
complex_a_2Asset class | General asset class, for example Sewer Gravity Pipe or Sewer Pipe. | |
complex_a_3Asset subtype | More specific asset subtype, such as Sewer Pressure Pipe, Sewer Pressure Siphon, Sewer Gravity Trunk Pipe or an overflow pipe. | |
complex_a_4Asset group | Top-level asset group, recorded as Sewer Pipe. | |
complex_a_5Catchment | Sewer service area or wastewater treatment plant catchment the pipe belongs to, such as Rubyanna, Millbank or Thabeban. | |
dimension_iDimension | mm | Additional recorded dimension of the pipe, blank for most rows. |
dimensio_1Dimension unit | Unit for the dimension value, recorded as mm where present. | |
downstreamDownstream invert level | m | Recorded downstream measurement for the pipe segment, in metres. |
downstre_1Downstream unit | Unit for the downstream value, recorded as m. | |
local_gov_arService area | Sewer service area the pipe sits in, such as Bundaberg Sewer Service Area. | |
pipe_classPipe class | Pressure or stiffness rating of the pipe, for example PN9 Series1, K-9 or SEH SN10. | |
pipe_depthPipe depth | m | Depth of the pipe below ground in metres. |
pipe_diametPipe diameter | mm | Nominal internal diameter of the pipe in millimetres. |
pipe_diam_1Pipe diameter unit | Unit for pipe diameter, recorded as mm. | |
pipe_lengthPipe length | m | Length of the pipe segment in metres. |
pipe_materiPipe material | Material the pipe is made from, such as DICL, vitrified clay, asbestos cement or uPVC. | |
upstream_inUpstream invert level | m | Recorded upstream measurement for the pipe segment, in metres. |
upstream_1Upstream unit | Unit for the upstream value, recorded as m. |