Port Pirie Air Quality Lead Readings (High Volume Sampler)
Validated airborne lead (Pb) concentrations measured by high volume samplers at monitoring stations in Port Pirie, South Australia, from 2009 to December 2025. Each row is one sampling date with lead readings in micrograms per cubic metre (µg/m³) for up to four stations, as total suspended particles (TSP) and, at one station, PM10. A caller gets 1,592 rows that can be searched and filtered or fetched by record ID.
Endpoints
Port Pirie Air Quality Lead Readings (High Volume Sampler): search
/v1/records/port-pirie-air-quality-lead-high-volume-sampler/search10¢ per callServed by /v1/records/{slug}/search, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
q | Words to find (prefix match, all must appear) in: sample date. |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Records per page, 1 to 50 (default 25). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/records/port-pirie-air-quality-lead-high-volume-sampler/search?q=1%2F01%2F2009' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
Port Pirie Air Quality Lead Readings (High Volume Sampler): one record
/v1/records/port-pirie-air-quality-lead-high-volume-sampler/{record_key}5¢ per callServed by /v1/records/{slug}/{record_key}, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
record_key | The record's record id. |
fields | Comma-separated field slugs (below). Omit for all. |
curl -X GET 'https://api.microburbs.com.au/v1/records/port-pirie-air-quality-lead-high-volume-sampler/1' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
Port Pirie, South Australia (Spencer Gulf), with 1,592 rows dated from 1 January 2009 to 9 December 2025. Four stations are included: Port Pirie West, Oliver Street, Ellen Street and Frank Green Park. Current to 2026-01-22; refreshed As published (no fixed schedule stated).
What it is
A register of validated lead concentrations in air at Port Pirie monitoring stations on the Spencer Gulf. Each row holds a sample date and the lead result for each station: Port Pirie West, Oliver Street, Ellen Street and Frank Green Park. Results are in µg/m³.
What it shows
It shows how airborne lead varies by station and over time in Port Pirie. Values range from 0.01 to 8.21 µg/m³ at Port Pirie West and up to 32.07 µg/m³ at Ellen Street. Oliver Street also reports a PM10 lead fraction, up to 2.84 µg/m³.
Why use it
Lead exposure in a smelter town is a health, planning and property-risk concern. Analysts can use these readings to compare locations within Port Pirie, track long-run trends and check exceedances against air quality standards. Developers and AI agents can use it as local environmental context for the area.
How it is built
We load the validated station results as published into one table, with one row per sampling date and one column per station and measure. Blank cells are kept blank where no result was reported. The dates are stored as text in day/month/year form. The data covers Port Pirie only, and the stations do not all report on every date.
Shortcomings
- Oliver Street TSP lead, Oliver Street PM10 lead and Frank Green Park are each blank for about 34% of rows, so station comparisons cover different sets of dates.
- Dates are text in day/month/year format and are not guaranteed to be evenly spaced, so check the sampling interval before calculating averages or trends.
- Values are not a continuous record. Each row is one sample result, not a daily or annual average, and they can't be compared directly with annual or rolling standards without aggregation.
- The Frank Green Park column name does not say lead, and it is assumed to be TSP lead in µg/m³. Very high maxima, such as 32.07 µg/m³ at Ellen Street, are in the data and haven't been separately checked.
Fields
| Field | Unit | Description |
|---|---|---|
record_idRecord ID | Identifier for the row, used to fetch a single record. | |
dateSample date | Date of the sample, as text in day/month/year form. | |
ptp03_port_pirie_west_tsp_lead_ug_m3Port Pirie West TSP lead | µg/m³ | Lead in total suspended particles measured at the Port Pirie West station (about 4% blank). |
ptp01_port_pirie_oliver_street_tsp_lead_ug_m3Oliver Street TSP lead | µg/m³ | Lead in total suspended particles measured at the Oliver Street station (about 34% blank). |
ptp01_port_pirie_oliver_street_pm10_lead_ug_m3Oliver Street PM10 lead | µg/m³ | Lead in the PM10 particle fraction measured at the Oliver Street station (about 34% blank). |
ptp04_port_pirie_ellen_street_tsp_lead_ug_m3Ellen Street TSP lead | µg/m³ | Lead in total suspended particles measured at the Ellen Street station (about 2% blank). |
ptp05_port_pirie_frank_green_park_tsp_ug_m3Frank Green Park TSP lead | µg/m³ | Lead in total suspended particles measured at the Frank Green Park station (about 34% blank). |
Data source: NSW Government