NSW BASIX New Single Dwelling Certificates 2011-12 to 2018-19
A register of 268,558 sustainability certificates for new single dwellings in New South Wales, issued between July 2011 and June 2019. Each row records the dwelling's size, water and energy targets and scores, fixtures, hot water, heating, cooling, lighting, pool and solar choices. Callers can search by text, filter by location or year and fetch a record by project ID.
Endpoints
NSW BASIX New Single Dwelling Certificates 2011-12 to 2018-19: search
/v1/records/nsw-new-single-dwelling-sustainability-certificates/search10¢ per callServed by /v1/records/{slug}/search, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
q | Words to find (prefix match, all must appear) in: certificate date, financial year, regional or metropolitan nsw, lga (2016 boundaries). |
where | Exact-match filter `field:value`, repeatable, on: `financial_year`, `regional_or_metropolitan_nsw`, `dwelling_type`. |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Records per page, 1 to 50 (default 25). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/records/nsw-new-single-dwelling-sustainability-certificates/search?q=2013-01-25' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
NSW BASIX New Single Dwelling Certificates 2011-12 to 2018-19: one record
/v1/records/nsw-new-single-dwelling-sustainability-certificates/{record_key}5¢ per callServed by /v1/records/{slug}/{record_key}, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
record_key | The record's project id. |
fields | Comma-separated field slugs (below). Omit for all. |
curl -X GET 'https://api.microburbs.com.au/v1/records/nsw-new-single-dwelling-sustainability-certificates/353660' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
New South Wales, both metropolitan and regional LGAs, postcodes 2000 to 3644. 268,558 rows with certificate dates from 1 July 2011 to the 2018/2019 financial year. Only new single dwellings are included, so alterations and multi-dwelling developments are not covered. Current to 2025-11-13; refreshed One-off. The series stops at the 2018/2019 financial year and is not expected to be updated..
What it is
One row per BASIX certificate for a new single dwelling in NSW, covering financial years 2011/2012 to 2018/2019. Each row holds the certificate date, location (LGA, suburb, postcode), dwelling type and size, and the water and energy commitments made for the build.
What it shows
It shows the sustainability features committed to in new homes: water and energy targets against scores, fixture star ratings, rainwater tanks, water sources, hot water systems, heating and cooling types, lighting, pools, spas and photovoltaic capacity. It lets you compare these choices across places and years.
Why use it
Analysts can measure how new housing design varies by area, for example tank uptake, solar installation, gas versus electric appliances or typical floor and site size. It also supports area profiling and screening of new-build stock.
How it is built
We load the certificate records as supplied and expose them as a searchable register keyed by project ID. Column names are standardised, and values are kept as recorded, so spelling and capitalisation (for example suburb names) vary. Many optional fields are blank where the original entry left them out.
Shortcomings
- Records are certificates issued at the design or approval stage, not confirmed as-built outcomes. Completion receipt date is blank for about 48% of rows, so many certificates cannot be matched to a completed dwelling.
- Several fields are often blank: NatHERS equivalent star rating (57%), low water species area (48%), heating and cooling ratings (39% to 53%), and kitchen lighting (33%). Stormwater tank volume is blank for about 99%. Do not treat blanks as zero.
- Site area has extreme values, up to 9,375,000 m², which are probably rural holdings or entry errors. Check outliers before averaging.
- Text values are not standardised. Suburb capitalisation varies, and some suburb values combine several localities. Rating labels differ by period (for example 'new rating' variants), and postcode is stored as a number.
Fields
| Field | Unit | Description |
|---|---|---|
project_idProject ID | Identifier of the certificate project, usable as a key to fetch a record. | |
certificate_dateCertificate date | Date the certificate was issued. | |
financial_yearFinancial year | Financial year of the certificate, for example 2016/2017. | |
regional_or_metropolitan_nswRegional or metropolitan NSW | Whether the dwelling is in a regional or metropolitan part of NSW. | |
lga_2016_nameLGA (2016 boundaries) | Local government area name using 2016 boundaries. | |
suburbSuburb | Suburb or locality as recorded, with inconsistent capitalisation. | |
postcodePostcode | Postcode of the dwelling, stored as a number. | |
completion_receipt_dateCompletion receipt date | Date a completion receipt was recorded, blank for about 48% of rows. | |
dwelling_typeDwelling type | Type of dwelling, such as separate house, attached dwelling or single unit. | |
no_of_bedroomsNumber of bedrooms | count | Number of bedrooms in the dwelling, from 0 to 17. |
site_area_m2Site area | m² | Area of the site in square metres. |
total_floor_areaTotal floor area | m² | Total floor area of the dwelling in square metres. |
garden_lawn_area_m2Garden and lawn area | m² | Area of garden and lawn in square metres. |
low_water_species_area_m2Low water species area | m² | Part of the garden planted with low-water-use species, blank for about 48% of rows. |
water_targetWater target | % | Required water saving target for the dwelling, from 0 to 40. |
water_scoreWater score | % | Water saving score achieved by the design, up to 100. |
energy_targetEnergy target | % | Required energy saving target for the dwelling, from 25 to 50. |
energy_scoreEnergy score | % | Energy saving score achieved by the design, from 25 to 100. |
thermal_comfort_methodThermal comfort method | Assessment method used for thermal comfort: DIY, Simulation or Rapid. | |
nat_hers_equivalent_star_ratingNatHERS equivalent star rating | stars | Equivalent thermal performance star rating, from 3 to 10, blank for about 57% of rows. |
showerhead_ratingShowerhead rating | Water efficiency star rating of showerheads, sometimes with a flow range. | |
toilet_ratingToilet rating | Water efficiency star rating of toilets. | |
kitchen_taps_ratingKitchen taps rating | Water efficiency star rating of kitchen taps. | |
bathroom_taps_ratingBathroom taps rating | Water efficiency star rating of bathroom taps. | |
rw_tank_roof_collection_area_m2Rainwater tank roof collection area | m² | Roof area draining to the rainwater tank, blank where no tank data is given. |
rw_tank_volume_lRainwater tank volume | L | Capacity of the rainwater tank in litres. |
stormwater_tank_volume_lStormwater tank volume | L | Capacity of the stormwater tank in litres, present in only about 1% of rows. |
reticulated_water_schemeReticulated water scheme | Name of the alternative reticulated water scheme serving the site, blank for about 89% of rows. | |
water_source_all_hot_waterWater source for hot water | Water source supplying all hot water. | |
water_source_toiletsWater source for toilets | Water source supplying toilets, such as rainwater tank or stormwater tank. | |
water_source_householdWater source for household | Water source for general household use. | |
water_source_garden_lawnWater source for garden and lawn | Water source for irrigating garden and lawn. | |
water_source_laundryWater source for laundry | Water source supplying the laundry. | |
pool_volume_k_lPool volume | kL | Volume of the swimming pool in kilolitres, blank where there is no pool. |
spa_volume_k_lSpa volume | kL | Volume of the spa in kilolitres, blank where there is no spa. |
hot_water_systemHot water system | Type of hot water system, such as gas storage, electric instantaneous or solar. | |
hot_water_system_ratingHot water system rating | Efficiency rating of the hot water system, as a star band or REC range, or not specified. | |
heating_living_room_typeLiving room heating type | Type of active heating in the living rooms. | |
heating_living_room_ratingLiving room heating rating | Efficiency rating of living room heating, blank for about 39% of rows. | |
heating_bedroom_typeBedroom heating type | Type of active heating in the bedrooms. | |
heating_bedroom_ratingBedroom heating rating | Efficiency rating of bedroom heating, blank for about 49% of rows. | |
cooling_living_room_typeLiving room cooling type | Type of active cooling in the living rooms, such as airconditioning or ceiling fans. | |
cooling_living_room_ratingLiving room cooling rating | Efficiency rating of living room cooling, blank for about 45% of rows. | |
cooling_bedroom_room_typeBedroom cooling type | Type of active cooling in the bedrooms. | |
cooling_bedroom_room_ratingBedroom cooling rating | Efficiency rating of bedroom cooling, blank for about 53% of rows. | |
lighting_no_living_rooms_energy_efficientEnergy-efficient lighting, living rooms | count | Number of living rooms with energy-efficient lighting. |
lighting_no_bedrooms_energy_efficientEnergy-efficient lighting, bedrooms | count | Number of bedrooms with energy-efficient lighting. |
lighting_kitchen_energy_efficientEnergy-efficient lighting, kitchen | Whether the kitchen has energy-efficient lighting, blank for about 33% of rows. | |
pool_heatingPool heating | Heating method for the pool, blank where there is no pool. | |
spa_heatingSpa heating | Heating method for the spa, blank where there is no spa. | |
oven_cooktop_typeOven and cooktop type | Fuel type of the cooktop and oven, such as gas or electric. | |
photovoltaic_output_k_wPhotovoltaic output | kW | Rated output of the photovoltaic system in kilowatts, blank for about 93% of rows. |
Data source: NSW Government