NSW BASIX Dwelling Certificates 2011-2020
A register of about 299,000 BASIX sustainability certificates for new single and multi-unit dwellings in New South Wales, issued from July 2011 to 2020. Each row gives the location, dwelling type, size, water and energy targets and scores, and the fixtures and systems committed to, such as hot water, heating, cooling, rainwater tanks and lighting.
Endpoints
NSW BASIX Dwelling Certificates 2011-2020: search
/v1/records/nsw-basix-dwelling-certificates-2011-2020/search10¢ per callServed by /v1/records/{slug}/search, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
q | Words to find (prefix match, all must appear) in: certificate date, financial year, regional or metropolitan nsw, lga (2016 boundaries). |
where | Exact-match filter `field:value`, repeatable, on: `financial_year`, `regional_or_metropolitan_nsw`, `dwelling_type`. |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Records per page, 1 to 50 (default 25). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/records/nsw-basix-dwelling-certificates-2011-2020/search?q=2011-07-07' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
NSW BASIX Dwelling Certificates 2011-2020: one record
/v1/records/nsw-basix-dwelling-certificates-2011-2020/{record_key}5¢ per callServed by /v1/records/{slug}/{record_key}, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
record_key | The record's project id. |
fields | Comma-separated field slugs (below). Omit for all. |
curl -X GET 'https://api.microburbs.com.au/v1/records/nsw-basix-dwelling-certificates-2011-2020/385906' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
New South Wales, with certificate dates starting on 1 July 2011 and running through the 2019-2020 financial year. The table has 299,019 rows. Postcodes range from 2008 to 2850, and LGAs use 2016 names. Both metropolitan and regional NSW are included. Current to 2025-10-18; refreshed One-off historical release; not expected to update..
What it is
This is a record-level register of BASIX (Building Sustainability Index) certificates for new dwellings in NSW. Single dwelling and multi-dwelling certificates are combined into one table, with one row per certificate. Each row describes the dwelling, its site, and the water and energy commitments made at certification.
What it shows
It shows where and when new dwellings were certified, by LGA, suburb, postcode and financial year. It shows dwelling type, bedrooms, site and floor area, and garden area. It also shows the water and energy targets and scores, fixture ratings, water sources, hot water, heating and cooling systems, cooktop type and lighting.
Why use it
Analysts can use it to track new housing activity and the mix of dwelling types across NSW over a decade. It also supports work on the energy and water design of new homes, such as how common rainwater tanks, heat pump hot water or gas cooktops are in a given area. Developers and researchers can benchmark typical design choices by LGA or by metropolitan versus regional NSW.
How it is built
We load the certificate listings for single and multi-dwelling projects and combine them into one searchable table keyed by project ID. Values are kept as recorded on the certificate, so text such as suburb names appears as entered. Several columns are empty across all rows or most rows.
Shortcomings
- Certificates record design commitments at approval, not as-built or measured performance, so they do not show actual energy or water use.
- Suburb names are free text and contain spelling and case errors (for example 'Maount Warrigal' and 'HOBARTVILLE'), so group by postcode or LGA where possible.
- Many fields are empty: completion receipt date, NatHERS star rating, storeys and low water species area are blank for large shares of rows, and stormwater tank, pool, spa, reticulated scheme and photovoltaic fields are blank for every row.
- Site area has extreme outliers (up to 2,407,000 m²), and water score is 40% on every row, so it does not differentiate between dwellings.
Fields
| Field | Unit | Description |
|---|---|---|
project_idProject ID | Identifier of the certificate project, usable as the key for fetching a row. | |
certificate_dateCertificate date | Date the certificate was issued. | |
financial_yearFinancial year | Financial year in which the certificate was issued, for example 2017-2018. | |
regional_or_metropolitan_nswRegional or metropolitan NSW | Whether the dwelling is in metropolitan or regional NSW. | |
lga_2016_nameLGA (2016 boundaries) | Name of the local government area the dwelling is in, using 2016 boundaries. | |
suburbSuburb | Suburb as entered on the certificate, with inconsistent spelling and case. | |
postcodePostcode | Postcode of the dwelling. | |
completion_receipt_dateCompletion receipt date | Date a completion receipt was recorded; blank for most or all rows. | |
dwelling_typeDwelling type | Type of dwelling, such as separate house, attached dwelling or single unit. | |
no_of_bedroomsNumber of bedrooms | count | Number of bedrooms in the dwelling, from 0 to 16. |
site_area_m2Site area | m² | Area of the site in square metres. |
total_floor_areaTotal floor area | m² | Total floor area of the dwelling in square metres. |
garden_lawn_area_m2Garden and lawn area | m² | Area of garden and lawn on the site in square metres. |
low_water_species_area_m2Low water species area | m² | Area planted with low water use species; recorded as 0 where present. |
water_targetWater target | % | Required percentage reduction in potable water use, from 20 to 40. |
water_scoreWater score | % | Water reduction score achieved by the design; 40 on every row. |
energy_targetEnergy target | % | Required percentage reduction in greenhouse gas emissions from energy use, from 25 to 50. |
energy_scoreEnergy score | % | Energy reduction score achieved by the design, from 25 to 59. |
storeysStoreys | count | Number of storeys, 1 or 2; blank for most rows. |
thermal_comfort_methodThermal comfort method | Method used to assess thermal comfort, such as Rapid or DIY. | |
nat_hers_equivalent_star_ratingNatHERS equivalent star rating | Equivalent NatHERS thermal star rating; blank for most or all rows. | |
showerhead_ratingShowerhead rating | Water efficiency star rating band of the showerheads, with flow range in litres per minute. | |
toilet_ratingToilet rating | Water efficiency star rating of the toilets, or waterless. | |
kitchen_taps_ratingKitchen taps rating | Water efficiency star rating of kitchen taps. | |
bathroom_taps_ratingBathroom taps rating | Water efficiency star rating of bathroom taps. | |
rw_tank_roof_collection_area_m2Rainwater tank roof collection area | m² | Roof area draining to the rainwater tank; blank where there is no tank. |
rw_tank_volume_lRainwater tank volume | L | Capacity of the rainwater tank in litres; blank where there is no tank. |
stormwater_tank_volume_lStormwater tank volume | L | Capacity of any stormwater tank; blank on all rows. |
reticulated_water_schemeReticulated water scheme | Reticulated alternative water scheme connected; blank on all rows. | |
water_source_all_hot_waterWater source for hot water | Source of water supplying all hot water, such as town supply or rainwater tank. | |
water_source_toiletsWater source for toilets | Source of water for toilets, such as town supply, rainwater tank or greywater system. | |
water_source_householdWater source for household use | Source of water for general household use. | |
water_source_garden_lawnWater source for garden and lawn | Source of water for garden and lawn irrigation. | |
water_source_laundryWater source for laundry | Source of water for the laundry. | |
pool_volume_k_lPool volume | kL | Volume of any swimming pool in kilolitres; blank on all rows. |
spa_volume_k_lSpa volume | kL | Volume of any spa in kilolitres; blank on all rows. |
hot_water_systemHot water system | Type of hot water system, such as electric heat pump or solar with gas boost. | |
hot_water_system_ratingHot water system rating | Rating of the hot water system; may read 'please select' or 'not specified'. | |
heating_living_room_typeLiving room heating type | Type of heating system in the living rooms. | |
heating_living_room_ratingLiving room heating rating | Efficiency rating of living room heating, using old or new label scales; often blank. | |
heating_bedroom_typeBedroom heating type | Type of heating system in the bedrooms. | |
heating_bedroom_ratingBedroom heating rating | Efficiency rating of bedroom heating; blank for most rows. | |
cooling_living_room_typeLiving room cooling type | Type of cooling system in the living rooms, including no active cooling. | |
cooling_living_room_ratingLiving room cooling rating | Efficiency rating of living room cooling, as star or EER band; often blank. | |
cooling_bedroom_typeBedroom cooling type | Type of cooling system in the bedrooms. | |
cooling_bedroom_ratingBedroom cooling rating | Efficiency rating of bedroom cooling; blank for most rows. | |
lighting_no_living_rooms_energy_efficientEnergy efficient lighting, living rooms | count | Number of living room lights specified as energy efficient. |
lighting_no_bedrooms_energy_efficientEnergy efficient lighting, bedrooms | count | Number of bedroom lights specified as energy efficient. |
lighting_kitchen_energy_efficientEnergy efficient kitchen lighting | Whether kitchen lighting is specified as energy efficient (true or false). | |
pool_heatingPool heating | Type of pool heating; blank on all rows. | |
spa_heatingSpa heating | Type of spa heating; blank on all rows. | |
oven_cooktop_typeOven and cooktop type | Fuel types of the cooktop and oven, such as gas cooktop with electric oven. | |
photovoltaic_output_k_wPhotovoltaic output | kW | Rated output of any solar photovoltaic system; blank on all rows. |
Data source: NSW Government