Microplastic Particle Size Measurements from Seawater Separation Trials
A 200-row register of length and width measurements for individual high-density polyethylene (HDPE) microplastic particles, recorded during laboratory trials of microplastic separation methods on seawater samples in Townsville in 2017. A caller can search and filter rows and fetch them by key. Each row holds nine repeated blocks of particle ID, length, width and sample label.
Endpoints
Microplastic Particle Size Measurements from Seawater Separation Trials: search
/v1/records/microplastic-particle-size-seawater-separation-trials/search10¢ per callServed by /v1/records/{slug}/search, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
q | Words to find (prefix match, all must appear) in: sample number (block 1), sample number (block 2), sample number (block 3), sample number (block 4). |
where | Exact-match filter `field:value`, repeatable, on: `sample_number`, `sample_number_2`, `sample_number_2_2`. |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Records per page, 1 to 50 (default 25). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/records/microplastic-particle-size-seawater-separation-trials/search?q=SAMPLE%201' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
Microplastic Particle Size Measurements from Seawater Separation Trials: one record
/v1/records/microplastic-particle-size-seawater-separation-trials/{record_key}5¢ per callServed by /v1/records/{slug}/{record_key}, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
record_key | The record's microplastic id (block 1). |
fields | Comma-separated field slugs (below). Omit for all. |
curl -X GET 'https://api.microburbs.com.au/v1/records/microplastic-particle-size-seawater-separation-trials/1' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
Laboratory experiments in Townsville, Queensland, carried out in 2017, with 200 rows. It describes no geographic area and has no suburb, LGA or coordinate fields. The dataset's listed start date is 24 September 2021, which is a record date, not the experiment date. Current to 2025-06-23; refreshed One-off.
What it is
Particle-level size measurements (length and width) of HDPE microplastics used as a model plastic in lab experiments. The experiments compared common separation techniques: visual sorting, density separation, acid digestion and enzyme digestion. Each row holds up to nine side-by-side measurement blocks, each with a particle ID, length, width and sometimes a sample label.
What it shows
It shows the size range of the HDPE particles measured. Lengths run from 145.4 to 5,022 across the blocks, and widths from 126.0 to 5,148. Particle IDs within the repeated blocks run from 1 to 10. It can be used to check whether particle size changed under different treatments, though the treatment for each block is not labelled in the columns.
Why use it
Analysts who study microplastic pollution need to know whether extraction methods bias or damage the particles they count. Particle dimensions let them compare size distributions between methods and judge how reliable recovery and counting are. The data is useful as a method-validation reference, not as a measure of pollution in any place.
How it is built
The values were measured on particles in laboratory experiments in Townsville in 2017, then compiled into a wide table. Repeated column groups carry numeric suffixes such as _2 and _2_2 for each additional block. The first block is filled for all 200 rows. The other blocks are filled for about 24 to 25 percent of rows, and sample labels for about 2 percent. The meaning of each block (which treatment it records) is not stated in the columns.
Shortcomings
- The layout is wide and repeated: nine blocks with suffixed names such as length_m_2_2. Nothing in the columns says which treatment, replicate or method each block represents, so comparing methods needs outside documentation.
- Sample labels are blank for about 98 percent of rows, and every block after the first is blank for about 75 percent of rows. You cannot reliably link most measurements back to a sample.
- The _m suffix on length and width most likely means micrometres, since values of 126 to 5,148 are plausible for particles and not for metres. The unit is inferred, so confirm it before use.
- Measurements cover only HDPE spiked into seawater in one lab, with no recovery counts or chemical results. The data does not describe microplastic levels in the environment and cannot be generalised to other polymers.
Fields
| Field | Unit | Description |
|---|---|---|
microplastic_id_numberMicroplastic ID (block 1) | Identifier of the measured particle in the first block, held as text. | |
length_mLength (block 1) | µm | Measured particle length in the first block, from 145.4 to 3,836. |
width_mWidth (block 1) | µm | Measured particle width in the first block, from 126.0 to 5,022. |
sample_numberSample number (block 1) | Sample label such as SAMPLE 1 to SAMPLE 5 for the first block, blank for 98% of rows. | |
microplastic_id_number_2Microplastic ID (block 2) | Particle number from 1 to 10 in the second block, blank for 75% of rows. | |
length_m_2Length (block 2) | µm | Measured particle length in the second block, from 694.4 to 2,960. |
width_m_2Width (block 2) | µm | Measured particle width in the second block, from 657.5 to 4,084. |
sample_number_2Sample number (block 2) | Sample label for the second block, blank for 98% of rows. | |
microplastic_id_number_2_2Microplastic ID (block 3) | Particle number from 1 to 10 in the third block, blank for 75% of rows. | |
length_m_2_2Length (block 3) | µm | Measured particle length in the third block, from 675.1 to 5,017. |
width_m_2_2Width (block 3) | µm | Measured particle width in the third block, from 126.0 to 5,148. |
sample_number_2_2Sample number (block 3) | Sample label for the third block, blank for 98% of rows. | |
microplastic_id_number_2_2_2Microplastic ID (block 4) | Particle number from 1 to 10 in the fourth block, blank for 75% of rows. | |
length_m_2_2_2Length (block 4) | µm | Measured particle length in the fourth block, from 666.1 to 2,402. |
width_m_2_2_2Width (block 4) | µm | Measured particle width in the fourth block, from 535.4 to 5,036. |
sample_number_2_2_2Sample number (block 4) | Sample label for the fourth block, blank for 98% of rows. | |
microplastic_id_number_2_2_2_2Microplastic ID (block 5) | Particle number from 1 to 10 in the fifth block, blank for 75% of rows. | |
length_m_2_2_2_2Length (block 5) | µm | Measured particle length in the fifth block, from 695.4 to 3,128. |
width_m_2_2_2_2Width (block 5) | µm | Measured particle width in the fifth block, from 661.5 to 3,654. |
sample_number_2_2_2_2Sample number (block 5) | Sample label for the fifth block, blank for 98% of rows. | |
microplastic_id_number_2_2_2_2_2Microplastic ID (block 6) | Particle number from 1 to 10 in the sixth block, blank for 75% of rows. | |
length_m_2_2_2_2_2Length (block 6) | µm | Measured particle length in the sixth block, from 793.0 to 2,925. |
width_m_2_2_2_2_2Width (block 6) | µm | Measured particle width in the sixth block, from 621.5 to 3,403. |
sample_number_2_2_2_2_2Sample number (block 6) | Sample label for the sixth block, blank for 98% of rows. | |
microplastic_id_number_2_2_2_2_2_2Microplastic ID (block 7) | Particle number from 1 to 10 in the seventh block, blank for 75% of rows. | |
length_m_2_2_2_2_2_2Length (block 7) | µm | Measured particle length in the seventh block, from 177.0 to 2,648. |
width_m_2_2_2_2_2_2Width (block 7) | µm | Measured particle width in the seventh block, from 577.2 to 3,537. |
sample_number_2_2_2_2_2_2Sample number (block 7) | Sample label for the seventh block, blank for 98% of rows. | |
microplastic_id_number_2_2_2_2_2_2_2Microplastic ID (block 8) | Particle number from 1 to 10 in the eighth block, blank for 75% of rows. | |
length_m_2_2_2_2_2_2_2Length (block 8) | µm | Measured particle length in the eighth block, from 623.0 to 2,486. |
width_m_2_2_2_2_2_2_2Width (block 8) | µm | Measured particle width in the eighth block, from 168.0 to 3,624. |
sample_number_2_2_2_2_2_2_2Sample number (block 8) | Sample label for the eighth block, blank for 98% of rows. | |
microplastic_id_number_2_2_2_2_2_2_2_2Microplastic ID (block 9) | Particle number from 1 to 10 in the ninth block, blank for 75% of rows. | |
length_m_2_2_2_2_2_2_2_2Length (block 9) | µm | Measured particle length in the ninth block, from 149.0 to 2,594. |
width_m_2_2_2_2_2_2_2_2Width (block 9) | µm | Measured particle width in the ninth block, from 709.3 to 2,893. |
