Microclimate Sensor Readings (15-Minute Air, Wind and Particulates)
Readings from street-level microclimate sensors across the city, recorded in fifteen-minute increments from June 2020. Each row is one measurement of air temperature, relative humidity, barometric pressure, PM2.5, PM10 or average wind speed at a sensor site, with its unit, time and site identifiers. Some rows are averaged values labelled for comparison with official air quality reporting.
Endpoints
Microclimate Sensor Readings (15-Minute Air, Wind and Particulates): search
/v1/records/microclimate-sensor-readings-15-minute/search10¢ per callServed by /v1/records/{slug}/search, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
q | Words to find (prefix match, all must appear) in: local time, sensor id, measurement type, units. |
where | Exact-match filter `field:value`, repeatable, on: `local_time`, `sensor_id`, `type`. |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Records per page, 1 to 50 (default 25). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/records/microclimate-sensor-readings-15-minute/search?q=2023-11-29T22%3A15%3A02%2B00%3A00' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
Microclimate Sensor Readings (15-Minute Air, Wind and Particulates): one record
/v1/records/microclimate-sensor-readings-15-minute/{record_key}5¢ per callServed by /v1/records/{slug}/{record_key}, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
record_key | The record's reading id. |
fields | Comma-separated field slugs (below). Omit for all. |
curl -X GET 'https://api.microburbs.com.au/v1/records/microclimate-sensor-readings-15-minute/8110553' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
City-wide sensor sites, with readings from 10 June 2020 onward and no fixed end date. The profile sample has 56 rows and shows site_id values from 1009 to 1012. Sample times are in November 2023. Coverage of the full history may be larger than the sample. Current to 2025-06-26; refreshed Hourly, with readings in fifteen-minute increments.
What it is
A register of individual microclimate measurements taken by sensors installed at sites across the city. Each row holds one value for one measurement type at one sensor and time. Types include temperature and humidity, pressure, fine and coarse particulate matter, and wind speed.
What it shows
It shows how temperature, humidity, pressure, air particles and wind vary between locations and through the day. Additional rows flagged as 'epa' give 1-hour and 24-hour averages for temperature, humidity, PM2.5 and PM10, so they line up with official air quality reporting.
Why use it
Analysts can use it to study urban heat, air quality and wind exposure at a local scale, and to compare conditions between sites. It also helps with planning, environmental assessment and checking local conditions against official air quality readings.
How it is built
We load the sensor readings as individual rows. Each is keyed by an id and linked to a site through site_id, which can be joined to a separate sensor locations dataset. Not every sensor has a reading at every interval, so gaps occur. Sensor locations may change over time, which affects historical comparisons.
Shortcomings
- Not every sensor has a reading for every fifteen-minute interval, so series can have gaps.
- Sensor locations can change over time, so check site locations before comparing historical readings.
- Readings are in mixed units and types in one value column, so filter by type and units before aggregating.
- Maximum values (up to 1011.3) are mostly barometric pressure in hPa. Check the type and units before reading outliers, and treat unexpected values as possible sensor faults.
Fields
| Field | Unit | Description |
|---|---|---|
local_timeLocal time | Timestamp of the reading, given as an ISO 8601 date and time with a UTC offset. | |
idReading ID | Unique identifier of the reading row, used to fetch a record by key. | |
site_idSite ID | Numeric identifier of the sensor site, used to join to sensor location records. | |
sensor_idSensor ID | Identifier of the individual sensor at the site, such as 5a, 5b, 5c or 6. | |
valueReading value | Measured value, interpreted using the type and units fields. | |
typeMeasurement type | Code for what was measured, such as PM2.5, PM10, WS (wind speed) or TPH.RH (temperature, pressure and humidity group). Rows containing 'epa' are averaged for comparison with official air quality reporting. | |
unitsUnits | Unit of the value, such as km/h, C, hPa or %. | |
gatewayhub_idGateway hub ID | Identifier of the gateway hub that relayed the sensor's data. | |
site_statusSite status | Status code of the sensor site; the sample only contains the code C. |
