MicroburbsMicroburbs
Free sandbox: try any request below on the sample suburbs, no signup. For every suburb, create an API key.
Classic docs
Microburbs Property Data API
Dataset · Environment

Melbourne Microclimate Sensor Readings

Point features for outdoor climate sensors in central Melbourne, each carrying readings of air temperature, humidity, pressure, wind, particulate matter (PM2.5 and PM10) and noise. A caller gets the sensor location and its time-stamped readings, by suburb as GeoJSON or near an address.

Endpoints

Melbourne Microclimate Sensor Readings (map)

GET/v1/suburbs/{suburb_name}/layers/melbourne-microclimate-sensor-readings10¢ per call

Served by /v1/suburbs/{suburb_name}/layers/{slug}, which documents every parameter, the response shape and errors, and has a live playground.

Query parameterDescription
fieldsComma-separated field slugs (below). Omit for all.
limitFeatures per page, 1 to 500 (default 200).
offsetItems to skip, for the next page (`next_offset`).
curl -X GET 'https://api.microburbs.com.au/v1/suburbs/Melbourne/layers/melbourne-microclimate-sensor-readings' \
  -H 'Authorization: Bearer test'

test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.

Melbourne Microclimate Sensor Readings nearby

GET/v1/properties/{gnaf_id}/layers/melbourne-microclimate-sensor-readings/nearby10¢ per call

Served by /v1/properties/{gnaf_id}/layers/{slug}/nearby, which documents every parameter, the response shape and errors, and has a live playground.

Query parameterDescription
radius_mSearch radius in metres, 1 to 2000 (default 500).
fieldsComma-separated field slugs (below). Omit for all.
limitFeatures per page, 1 to 500 (default 200).
offsetItems to skip, for the next page (`next_offset`).
curl -X GET 'https://api.microburbs.com.au/v1/properties/GAVIC420724318/layers/melbourne-microclimate-sensor-readings/nearby' \
  -H 'Authorization: Bearer test'

test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.

About this dataset

Central Melbourne only, with a bounding box of roughly 144.952 to 144.983 east and -37.822 to -37.796 south. All features fall within the Melbourne suburb. The layer holds 1,031,461 rows. The received_at timestamps run from December 2022 (1671753712) to late November 2023 (1701213917), although the dataset's stated temporal range starts on 5 September 2024. Current to 2026-10-01; refreshed The source sensors report about every 15 minutes, but no update frequency is recorded for this layer, so treat it as as published..

What it is

A layer of about 1.03 million readings from fixed microclimate sensors in the Melbourne central area. Each row is one reading from one device, placed at a park pole or building rooftop. Readings cover air temperature, relative humidity, atmospheric pressure, wind speed and direction, gusts, PM2.5, PM10 and noise.

What it shows

It shows how local conditions differ between sensor sites and through the day, such as heat, wind exposure, air quality and noise levels. Because each reading is tied to a point, you can compare a park with a rooftop or a street canyon.

Why use it

Street-level conditions often differ from regional weather station figures. Analysts can use this to assess amenity, urban heat, air quality and noise around a site. It can also support environmental context for property and planning work in the Melbourne central area.

How it is built

We load the sensor readings and attach each one to the point location of its device. We serve them as map features with attributes, grouped by suburb or searched near an address. Sensors are sparse, so most addresses have no sensor close by. Not every sensor reports every value at every interval, so some fields are blank.

Shortcomings

  • Only a handful of sensors exist, all in the central city, so the data says little about suburbs elsewhere or about areas away from a device.
  • Readings are not guaranteed every 15 minutes. About 37% of rows have no minimum or maximum wind values or gust speed, and some intervals have no reading at all.
  • Timestamps in the rows end in November 2023, which does not match the dataset's stated date range from September 2024. Check the dates before relying on the data as current.
  • The sensors are mixed between rooftops and street-level poles, so readings from different sites are not directly like-for-like. Extreme values, such as PM2.5 up to 418, may be sensor faults or short local events and are not cleaned.

Fields

FieldUnitDescription
device_id
Device ID
Identifier of the sensor device that made the reading.
received_at
Received at
sTime the reading was received, as a Unix timestamp in seconds since 1 January 1970 UTC.
sensorlocation
Sensor location
Text description of where the sensor is mounted, such as a park pole or building rooftop.
minimumwinddirection
Minimum wind direction
degreesLowest wind direction recorded over the reporting interval, in degrees from north; blank for about 37% of rows.
averagewinddirection
Average wind direction
degreesAverage wind direction over the reporting interval, in degrees from north (0 to 359).
maximumwinddirection
Maximum wind direction
degreesHighest wind direction recorded over the reporting interval, in degrees from north; blank for about 37% of rows.
minimumwindspeed
Minimum wind speed
m/sLowest wind speed over the reporting interval; blank for about 37% of rows.
averagewindspeed
Average wind speed
m/sAverage wind speed over the reporting interval, up to 6.6 in this layer.
gustwindspeed
Gust wind speed
m/sPeak gust wind speed over the reporting interval, up to 10.7; blank for about 37% of rows.
airtemperature
Air temperature
°CAmbient air temperature at the sensor, ranging from 3.8 to 36.8.
relativehumidity
Relative humidity
%Relative humidity of the air at the sensor, ranging from 21.1 to about 99.8.
atmosphericpressure
Atmospheric pressure
hPaAtmospheric pressure at the sensor, ranging from 996.5 to 1029.0.
pm25
PM2.5 particulate matter
µg/m³Concentration of fine particles up to 2.5 micrometres across, ranging from 0 to 418.
pm10
PM10 particulate matter
µg/m³Concentration of particles up to 10 micrometres across, ranging from 0 to 452.
noise
Noise level
dBSound level measured at the sensor, ranging from 44.5 to 126.6.

Data source: City of Melbourne