MicroburbsMicroburbs
Free sandbox: try any request below on the sample suburbs, no signup. For every suburb, create an API key.
Classic docs
Microburbs Property Data API
Dataset · Environment

Kensington Air Quality Gaseous Pollutant Readings, Eastern Adelaide

Validated readings of ozone and nitrogen oxides (nitric oxide, calculated nitrogen dioxide and total NOx) from the Kensington air quality monitoring station in Eastern Adelaide. A caller gets 4,464 timestamped rows, searchable by text and filters and fetchable by record key, with concentrations in parts per million.

Endpoints

Kensington Air Quality Gaseous Pollutant Readings, Eastern Adelaide: search

GET/v1/records/kensington-air-quality-gaseous-pollutants/search10¢ per call

Served by /v1/records/{slug}/search, which documents every parameter, the response shape and errors, and has a live playground.

Query parameterDescription
qWords to find (prefix match, all must appear) in: date and time.
fieldsComma-separated field slugs (below). Omit for all.
limitRecords per page, 1 to 50 (default 25).
offsetItems to skip, for the next page (`next_offset`).
curl -X GET 'https://api.microburbs.com.au/v1/records/kensington-air-quality-gaseous-pollutants/search?q=1%2F12%2F2014%200%3A10' \
  -H 'Authorization: Bearer test'

test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.

Kensington Air Quality Gaseous Pollutant Readings, Eastern Adelaide: one record

GET/v1/records/kensington-air-quality-gaseous-pollutants/{record_key}5¢ per call

Served by /v1/records/{slug}/{record_key}, which documents every parameter, the response shape and errors, and has a live playground.

Query parameterDescription
record_keyThe record's record id.
fieldsComma-separated field slugs (below). Omit for all.
curl -X GET 'https://api.microburbs.com.au/v1/records/kensington-air-quality-gaseous-pollutants/1' \
  -H 'Authorization: Bearer test'

test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.

About this dataset

One monitoring station at Kensington, Eastern Adelaide, South Australia. The stated period runs from 1 January 2013 to 29 January 2020, but the 4,464 rows are far fewer than a continuous record over that span would give. The example timestamps are all from December 2014, so the rows may cover only part of the period. Current to 2025-06-25; refreshed As published. No update frequency is stated, and the data ends in January 2020, so it is effectively a historical, one-off series..

What it is

A register of short-interval gaseous air pollution measurements recorded at one fixed monitoring station at Kensington, in the Eastern Adelaide airshed. Each row is one timestamped reading with ozone and nitrogen oxide concentrations.

What it shows

It shows how ozone, nitric oxide, calculated nitrogen dioxide and total nitrogen oxide concentrations vary over time at the station. Values are in parts per million, and the timestamps allow analysis of daily and seasonal patterns.

Why use it

Useful for assessing local air quality, comparing readings with air quality standards, and understanding traffic-related and photochemical pollution in inner-eastern Adelaide. It can also add environmental context to neighbourhood analysis.

How it is built

We load the validated station readings and keep one row per timestamp. Values are instrument observations, not modelled estimates. Only ozone and nitrogen oxide fields are present. Carbon monoxide and sulfur dioxide appear in the dataset tags but are not among the fields provided. About 1% of values are missing in each measurement field.

Shortcomings

  • Single station only, so readings cannot be assumed to represent air quality across Eastern Adelaide or other suburbs.
  • The row count is much lower than the date range implies, so the series has gaps and may cover only some periods. Check the timestamps before trend analysis.
  • Some values are slightly negative (down to -0.002 ppm) because of instrument noise near zero. Treat them as effectively zero, not as real negative concentrations.
  • The date_time field is stored as text in day/month/year format, and readings are at about 10-minute intervals, so you must parse and aggregate it yourself.

Fields

FieldUnitDescription
record_id
Record ID
Identifier for the row, used to fetch a single reading by key.
date_time
Date and time
Date and time of the reading as text in day/month/year hour:minute format, for example 21/12/2014 10:10.
o3_uva_ppm
Ozone (UV absorption)
ppmOzone concentration measured by ultraviolet absorption, ranging from 0.001 to 0.05 ppm in the data.
no_chemiluminescence_ppm
Nitric oxide (NO)
ppmNitric oxide concentration measured by chemiluminescence, ranging from -0.002 to 0.034 ppm.
no2_calc_chemiluminescence_ppm
Nitrogen dioxide (NO2, calculated)
ppmNitrogen dioxide concentration calculated from chemiluminescence readings, ranging from -0.001 to 0.031 ppm.
nox_chemiluminescence_ppm
Total nitrogen oxides (NOx)
ppmTotal oxides of nitrogen concentration measured by chemiluminescence, ranging from -0.002 to 0.06 ppm.

Data source: NSW Government