Eastern Treatment Plant Daily Electricity Use, Melbourne
Daily electricity figures for the Eastern Treatment Plant, a large wastewater treatment plant in Melbourne's east. Each of the 2,588 rows gives grid electricity drawn through two supply feeders and electricity generated on site, all in kilowatt-hours, for one day. Callers can search and filter the rows or fetch a single row by its key.
Endpoints
Eastern Treatment Plant Daily Electricity Use, Melbourne: search
/v1/records/eastern-treatment-plant-daily-electricity-melbourne-2/search10¢ per callServed by /v1/records/{slug}/search, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
q | Words to find (prefix match, all must appear) in: record date. |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Records per page, 1 to 50 (default 25). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/records/eastern-treatment-plant-daily-electricity-melbourne-2/search?q=31%2F12%2F2013%2013%3A00' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
Eastern Treatment Plant Daily Electricity Use, Melbourne: one record
/v1/records/eastern-treatment-plant-daily-electricity-melbourne-2/{record_key}5¢ per callServed by /v1/records/{slug}/{record_key}, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
record_key | The record's row identifier. |
fields | Comma-separated field slugs (below). Omit for all. |
curl -X GET 'https://api.microburbs.com.au/v1/records/eastern-treatment-plant-daily-electricity-melbourne-2/1' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
One site, the Eastern Treatment Plant in Melbourne, Victoria. There are 2,588 daily rows. Example record dates run from 2015 to 2017, and the profile's temporal range starts on 2 September 2019 with no end date. The record dates and the stated range do not agree, so check the actual date span before relying on it. Current to 2026-06-25; refreshed As published; no update frequency is stated..
What it is
A register of daily electricity records for one wastewater treatment plant. Each row has the day, the grid consumption on feeder 1 and feeder 2, and the on-site electricity generation. All energy values are in kWh.
What it shows
It shows how much electricity the plant draws from the grid and how much it generates itself each day. Adding feeder 1 and feeder 2 gives total grid consumption. Adding generation to that gives total electricity use at the plant. Feeder values range up to 263,371 kWh (feeder 1) and 285,953 kWh (feeder 2). Daily generation reaches 171,445 kWh.
Why use it
It suits energy-intensity benchmarking of wastewater infrastructure and year-on-year comparison of usage. It can also be compared against weather such as temperature and rainfall. Analysts can estimate how much of the plant's demand is met by on-site generation.
How it is built
We hold the data as daily totals. They were summed from 15-minute grid meter readings on each supply feeder and from generation meter readings. Day boundaries are set in UTC, not Melbourne local time. The profile lists no gaps in the values, and zero appears as a minimum in every energy field. Zeros may be real outages or missing readings, and the data does not say which.
Shortcomings
- Day boundaries are in UTC, so a record date does not line up with a Melbourne calendar day. Example timestamps such as 14:00 and 13:00 reflect the daylight saving offset.
- Zero values occur in all three energy fields. They may be outages, a feeder not in use, or missing readings. Treat them with care in averages.
- Record dates are stored as text in day/month/year format, not as true date values. They need parsing before sorting or joining.
- The data covers one plant only. It has no weather, flow or load measures, so it cannot explain usage by itself. Accuracy and completeness are not guaranteed.
Fields
| Field | Unit | Description |
|---|---|---|
recorddateRecord date | Start of the day the totals cover, as day/month/year hour:minute text in UTC. | |
feeder1_kwhFeeder 1 grid consumption | kWh | Electricity drawn from the grid through supply feeder 1 over the day. |
feeder2_kwhFeeder 2 grid consumption | kWh | Electricity drawn from the grid through supply feeder 2 over the day. |
object_idRow identifier | Unique key for the row, used to fetch a single record. | |
generation_k_whOn-site electricity generation | kWh | Electricity generated at the plant over the day. |