Eastern Treatment Plant Utility Water (3W) Pipelines, Bangholme
Pipeline centrelines for the utility water (3W) network at the Eastern Treatment Plant wastewater facility, in the Bangholme and Carrum Downs area. A caller gets 360 line features with pipe name, type, size, material, construction and service status, returned as GeoJSON per suburb or near an address.
Endpoints
Eastern Treatment Plant Utility Water (3W) Pipelines, Bangholme (map)
/v1/suburbs/{suburb_name}/layers/eastern-treatment-plant-3w-pipelines-bangholme10¢ per callServed by /v1/suburbs/{suburb_name}/layers/{slug}, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/suburbs/Bangholme/layers/eastern-treatment-plant-3w-pipelines-bangholme' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
Eastern Treatment Plant Utility Water (3W) Pipelines, Bangholme nearby
/v1/properties/{gnaf_id}/layers/eastern-treatment-plant-3w-pipelines-bangholme/nearby10¢ per callServed by /v1/properties/{gnaf_id}/layers/{slug}/nearby, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
radius_m | Search radius in metres, 1 to 2000 (default 500). |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/properties/GAVIC420721087/layers/eastern-treatment-plant-3w-pipelines-bangholme/nearby' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
The Eastern Treatment Plant site, within the suburbs of Bangholme and Carrum Downs in Victoria. The layer holds 360 line features between about 145.158 and 145.186 longitude and -38.074 and -38.046 latitude, and all features fall inside a suburb. The temporal range starts on 2019-11-15. Current to 2025-06-25; refreshed As published; no fixed update schedule is stated. The layer is revised when completed projects or certified survey plans supply new information..
What it is
A line layer of 360 pipeline segments carrying utility water, known as 3W, inside a wastewater treatment plant. Each segment has identifiers, a plant area name, pipe dimensions, material, plan references and a service status.
What it shows
It shows the indicative location and route of onsite 3W pipes, which treatment area each one serves (for example effluent holding basins, sludge drying pans, odour treatment plant) and whether the pipe is in service or decommissioned. It also gives the as-constructed plan numbers that document each section.
Why use it
Anyone planning works near the plant, such as excavation, surveying or engineering design, can use it to find buried water assets that need protecting. It also supports asset management and maintenance work on the site.
How it is built
We take the pipeline centrelines and their attributes as supplied and serve them as map features, grouped by suburb and searchable near an address. Values are passed through as recorded, so blank and placeholder entries remain. Dates are held as text.
Shortcomings
- Pipework inside one treatment plant: of little use for a property or an area.
- Locations are indicative only and carry no guarantee of accuracy or completeness, so they should be confirmed on site before any excavation.
- Many attributes are blank: unit ID in 44% of rows, second unit ID in 46%, sub-area in 79%, material in 81%, and construction date in 83%.
- Several numeric fields (compkey, comptype, invert levels, height, grade) hold only zero, which is a placeholder rather than a measurement. Pipe length and width also contain zeros.
- Only a small share of rows have a service status change date (4% populated) or plan number (5%), so decommissioning history is incomplete. Dates are text, and capture and update dates mostly fall in 2009 to 2014.
Fields
| Field | Unit | Description |
|---|---|---|
mxunitidMaintenance unit ID | Combined identifier of the pipe from its start node to its end node, sometimes with the start part blank. | |
mxsiteidMaintenance site ID | Site code for the asset record; every row holds the same value, MWS. | |
compkeyComponent key | Component key number; it is 0 for every row, so it carries no information. | |
comptypeComponent type code | Component type number; it is 0 for every row. | |
unitidUnit ID | Identifier of the pipe's start asset; blank for 44% of rows. | |
unitid2Second unit ID | Identifier of the pipe's end asset; blank for 46% of rows. | |
unittypeUnit type | Asset type code; every row is 3WMAIN. | |
unittype_descUnit type description | Plain description of the pipe type, such as 3W Offtake, 3W PIPELINE or 3W PIPELINE TO TUNNEL. | |
sewer_namePlant area name | Name of the plant process or area the pipe serves, such as EFFLUENT HOLDING BASINS or ODOUR TREATMENT PLANT. | |
asset_idAsset ID | Short asset code for the section of the plant, such as MS90 or SB96; blank for 1% of rows. | |
subareaSub-area | Short code for a sub-area of the plant, such as TERT, PSB or GRS; blank for 79% of rows. | |
shapePipe cross-section shape | Cross-section shape code; every row is CIRC (circular). | |
materialPipe material | Pipe material code, such as PE, HDPE or COPPER; blank for 81% of rows. | |
upstream_ilUpstream invert level | m | Invert level at the upstream end; it is 0 for every row, so it is not recorded. |
downstream_ilDownstream invert level | m | Invert level at the downstream end; it is 0 for every row, so it is not recorded. |
pipe_lengthPipe length | m | Recorded length of the pipe segment, from 0 to about 987 metres. |
pipe_widthPipe width (diameter) | mm | Recorded pipe width, from 0 to 750; 0 means not recorded. |
pipe_heightPipe height | mm | Pipe height; it is 0 for every row, as it does not apply to circular pipes. |
gradePipe grade | Pipe grade or slope; it is 0 for every row, so it is not recorded. | |
date_of_constructionDate of construction | Date the pipe was built, held as text; blank for 83% of rows. | |
epms_sec_noAsset section number | Asset section reference linking the pipe to its as-constructed drawing set, such as C21/01. | |
asconst_plan_noAs-constructed plan number | Number of the as-constructed plan that documents the pipe, such as E90/02/104. | |
sourceData source type | How the record was derived, for example AS CONST, AS CONSTRUCTED or GRAPHICS. | |
method_of_captureMethod of capture | How the location was captured, such as DIGITAL DATA, COORDINATES or DIGITISED. | |
date_capturedDate captured | Date the feature was first captured, held as text. | |
date_last_updatedDate last updated | Date the record was last edited, held as text; blank for 1% of rows. | |
service_statusService status | Current status of the pipe: IN for in service or DEC for decommissioned. | |
service_status_chg_dateService status change date | Date the service status last changed, held as text; blank for 96% of rows. | |
service_status_plan_noService status plan number | Plan number that documents a status change; blank for 95% of rows. | |
commentsComments | Free-text notes on the pipe, such as relocation or links to a decommissioned hydrant; blank for 80% of rows. |