MicroburbsMicroburbs
Free sandbox: try any request below on the sample suburbs, no signup. For every suburb, create an API key.
Classic docs
Microburbs Property Data API
Dataset · Environment

Charlestown Temperature and Humidity Sensor Readings (Aug 2019 – Jul 2020)

Historical readings of air temperature and relative humidity from a network of street-level IoT sensors in and around Charlestown, NSW, recorded between 1 August 2019 and 31 July 2020. The dataset has 401,134 point records. Each record gives the reading time, device identity and name, temperature in degrees Celsius, humidity in per cent and the sensor's coordinates. Callers can retrieve them per suburb as GeoJSON or for sensors near an address.

Endpoints

Charlestown Temperature and Humidity Sensor Readings (Aug 2019 – Jul 2020) (map)

GET/v1/suburbs/{suburb_name}/layers/charlestown-temperature-humidity-sensor-readings-2019-20-210¢ per call

Served by /v1/suburbs/{suburb_name}/layers/{slug}, which documents every parameter, the response shape and errors, and has a live playground.

Query parameterDescription
fieldsComma-separated field slugs (below). Omit for all.
limitFeatures per page, 1 to 500 (default 200).
offsetItems to skip, for the next page (`next_offset`).
curl -X GET 'https://api.microburbs.com.au/v1/suburbs/Charlestown%20%28NSW%29/layers/charlestown-temperature-humidity-sensor-readings-2019-20-2' \
  -H 'Authorization: Bearer test'

test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.

Charlestown Temperature and Humidity Sensor Readings (Aug 2019 – Jul 2020) nearby

GET/v1/properties/{gnaf_id}/layers/charlestown-temperature-humidity-sensor-readings-2019-20-2/nearby10¢ per call

Served by /v1/properties/{gnaf_id}/layers/{slug}/nearby, which documents every parameter, the response shape and errors, and has a live playground.

Query parameterDescription
radius_mSearch radius in metres, 1 to 2000 (default 500).
fieldsComma-separated field slugs (below). Omit for all.
limitFeatures per page, 1 to 500 (default 200).
offsetItems to skip, for the next page (`next_offset`).
curl -X GET 'https://api.microburbs.com.au/v1/properties/GANSW711883092/layers/charlestown-temperature-humidity-sensor-readings-2019-20-2/nearby' \
  -H 'Authorization: Bearer test'

test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.

About this dataset

Charlestown (NSW), Speers Point and Whitebridge in the Lake Macquarie area of NSW. Sensor locations lie between about -32.978 and -32.961 latitude and 151.619 and 151.708 longitude. Readings run from 1 August 2019 to 31 July 2020 and total 401,134 records. Current to 2025-06-24; refreshed One-off. This is a closed historical series that ends on 31 July 2020 and is not expected to update..

What it is

A point layer of timestamped temperature and humidity observations from fixed outdoor sensors. Each row is one reading from one device, with the device's name and location attached. Devices are named after the street sites where they are installed, such as a church, a car park, a library and a highway intersection.

What it shows

It shows how air temperature and relative humidity varied over time at specific street sites around Charlestown across about a year. Because the sensors sit at different places, readings can be compared between sites to see local differences, which is useful for urban heat analysis. Recorded temperatures range from about 6.8 °C to 18.1 °C, and humidity from about 57.9% to 100%.

Why use it

Local microclimate readings help analysts study urban heat, comfort and environmental conditions at street level, which regional weather stations cannot resolve. They can inform planning, tree canopy and shading assessments, and comparisons between sites. They can also serve as a baseline against later sensor data.

How it is built

We load the sensor readings as point features and attach each one to the suburb it falls in, so you can query by suburb or by proximity to an address. Every record has a value for every field. All points fall inside a suburb. The sensors report through a community low-power wireless network, so gaps in transmission may leave missing periods for some devices.

Shortcomings

  • The series stops on 31 July 2020, so it does not describe current conditions.
  • Coverage is limited to a small number of fixed sensor sites in the Charlestown area, so it does not represent the wider region or whole suburbs.
  • The values in the profile come from only part of the period (the sample shows a winter range), so check the readings for the season you need. Readings may also have gaps or uneven intervals between devices.
  • Humidity reaches exactly 100% at times, which may reflect sensor saturation, and readings are raw sensor output without documented calibration or quality checks. Timestamps are stored as text with a +10:00 offset.

Fields

FieldUnitDescription
time
Reading time
Date and time of the reading as an ISO 8601 text timestamp with a +10:00 offset.
device_id
Device ID
Unique identifier of the sensor device that made the reading.
device_name
Device name
Descriptive name of the sensor, usually naming the street site where it is installed.
temperature_c
Air temperature
°CMeasured air temperature in degrees Celsius.
humidity
Relative humidity
%Measured relative humidity as a percentage.
latitude
Latitude
degreesLatitude of the sensor in decimal degrees (negative for the southern hemisphere).
longitude
Longitude
degreesLongitude of the sensor in decimal degrees.
location
Location
Sensor position as a text pair of latitude and longitude separated by a comma.

Data source: Lake Macquarie City Council