Brisbane River Moggill Reach Water Quality Buoy Readings
Raw, unvalidated sensor readings from a water quality monitoring buoy at Moggill Reach on the Brisbane River, covering about five weeks in April and May 2023. The dataset has 2,005 records, each combining water chemistry and optical readings (temperature, salinity, pH, dissolved oxygen, turbidity, chlorophyll, dissolved organic matter) with current-profiler readings (speed, direction, tilt).
Endpoints
Brisbane River Moggill Reach Water Quality Buoy Readings: search
/v1/records/brisbane-river-moggill-reach-water-quality-buoy/search10¢ per call| Query parameter | Description |
|---|---|
q | Words to find (prefix match, all must appear) in: timestamp, current sensor temperature (z-pulse only), chloride concentration, chloride sensor voltage. |
where | Exact-match filter `field:value`, repeatable, on: `dcs_dcs_temp_zpulse_only`, `sonde_values_chloride_mg_l`, `sonde_values_chloride_m_v`. |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Records per page, 1 to 50 (default 25). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/records/brisbane-river-moggill-reach-water-quality-buoy/search?q=Units' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
Brisbane River Moggill Reach Water Quality Buoy Readings: one record
/v1/records/brisbane-river-moggill-reach-water-quality-buoy/{record_key}5¢ per call| Query parameter | Description |
|---|---|
record_key | The record's record id. |
fields | Comma-separated field slugs (below). Omit for all. |
curl -X GET 'https://api.microburbs.com.au/v1/records/brisbane-river-moggill-reach-water-quality-buoy/1' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
One monitoring buoy at Moggill Reach, Brisbane River, Queensland. 2,005 records from about 4 April 2023 to 11 May 2023. Record numbers run from 1 to 2004. Current to 2025-11-11; refreshed One-off.
What it is
A time series of logged readings from one buoy-mounted water quality sonde and a current-profiling sensor at Moggill Reach, Brisbane River. Each row is one logging interval with a timestamp and a sequential record number. Many columns are instrument channels that were not fitted and are blank.
What it shows
It shows how temperature, conductivity, salinity, pH, dissolved oxygen, turbidity, chlorophyll, blue-green algae pigment and fluorescent dissolved organic matter varied at the site over roughly 4 April to 11 May 2023. It also shows buoy movement and water current readings such as speed, direction, heading and tilt.
Why use it
It lets analysts look at short-term estuarine water quality behaviour in the Brisbane River, such as tidal salinity swings, algal indicators and turbidity changes. It can support environmental screening, sensor research and comparison with other monitoring sites. Because it is unvalidated, it suits exploration more than reporting.
How it is built
We load the logged buoy records as published into a searchable register, with one row per logging record, fetchable by record key. Values are kept as recorded and are not corrected or gap-filled. Several instrument channels are empty for every row, and the record covers one site and one short period only.
Shortcomings
- The data is raw and unvalidated, so it may include sensor drift, fouling, spikes and other errors. Treat it with caution and don't use it for compliance or reporting.
- It covers a single site and only about five weeks in 2023, so it can't show seasonal or long-term trends.
- Some values are physically implausible, such as negative conductivity and negative fluorescence readings, which suggests calibration offsets or sensor faults. Several channels are empty for every row (chloride, nitrate, temperature on the profiler, ORP, PAR, rhodamine, gauge pressure). Some fields hold only a unit label, not a number.
- Some columns are constant, such as the blue-green algae cell count and the turbidity TSS field, which are 0 in every populated row. Treat them as unused channels. Roughly 3 to 4 per cent of rows have missing sensor values.
Fields
| Field | Unit | Description |
|---|---|---|
record_idRecord ID | Unique key for the row in this register. | |
timestampTimestamp | Date and time of the reading, as local logger text in YYYY-MM-DD HH:MM:SS form. | |
recordLogger record number | count | Sequential record number from the data logger, from 1 to 2004. |
dcs_abs_speedAbsolute current speed | Absolute water speed from the current sensor; the unit isn't stated. | |
dcs_abs_tiltAbsolute tilt | degrees | Absolute tilt of the current sensor. |
dcs_dcs_temp_zpulse_onlyCurrent sensor temperature (Z-Pulse only) | Temperature channel for Z-Pulse models; it is blank in every row and holds only a unit label. | |
dcs_directionCurrent direction | degrees | Direction of water flow measured by the current sensor. |
dcs_eth_vectorEast vector component | East-west component of the measured current vector; the unit isn't stated. | |
dcs_headingSensor heading | degrees | Compass heading of the current sensor. |
dcs_max_tiltMaximum tilt | degrees | Maximum tilt of the current sensor in the measurement interval. |
dcs_nth_vectorNorth vector component | North-south component of the measured current vector; the unit isn't stated. | |
dcs_ping_countPing count | count | Number of acoustic pings used for the measurement, between 40 and 50. |
dcs_sig_strengthSignal strength | dB | Strength of the returned signal at the current sensor. |
dcs_sp_stdSpeed standard deviation | Standard deviation of the current speed readings in the interval. | |
dcs_std_tiltTilt standard deviation | degrees | Standard deviation of the tilt readings in the interval. |
dcs_tilt_xTilt X | degrees | Tilt of the current sensor along the X axis. |
dcs_tilt_yTilt Y | degrees | Tilt of the current sensor along the Y axis. |
sonde_values_bga_pe_cellsm_lBlue-green algae (phycoerythrin) cell count | cells/mL | Estimated blue-green algae cell concentration; it is 0 in every populated row. |
sonde_values_bga_pe_rfuBlue-green algae (phycoerythrin) fluorescence | RFU | Phycoerythrin fluorescence in relative fluorescence units, an indicator of blue-green algae. |
sonde_values_bga_pe_ug_lBlue-green algae (phycoerythrin) concentration | µg/L | Estimated phycoerythrin pigment concentration; it can be negative. |
sonde_values_chloride_mg_lChloride concentration | Chloride sensor channel; it is blank in every row and holds only a unit label. | |
sonde_values_chloride_m_vChloride sensor voltage | Chloride sensor raw voltage; it is blank in every row and holds only a unit label. | |
sonde_values_chlorophyllChlorophyll (unlabelled channel) | Chlorophyll channel with no stated unit; it is 0 in every populated row. | |
sonde_values_chlorophyll_rfuChlorophyll fluorescence | RFU | Chlorophyll fluorescence in relative fluorescence units, an indicator of algal biomass. |
sonde_values_chlorophyll_ug_lChlorophyll concentration | µg/L | Estimated chlorophyll concentration from fluorescence. |
sonde_values_conductivity_n_lfNon-linear function conductivity | µS/cm | Conductivity calculated using a non-linear function, not temperature compensated. |
sonde_values_conductivity_usConductivity | µS/cm | Electrical conductivity of the water, not temperature compensated. |
sonde_values_depthSensor depth | m | Depth of the sonde below the water surface. |
sonde_values_external_tempWater temperature | °C | Water temperature from the external probe. |
sonde_values_f_dom_qsuFluorescent dissolved organic matter | QSU | Fluorescent dissolved organic matter in quinine sulfate units. |
sonde_values_f_dom_rfuFluorescent dissolved organic matter fluorescence | RFU | Fluorescent dissolved organic matter in relative fluorescence units. |
sonde_values_nitra_ledNitrate sensor LED | Nitrate sensor LED channel; it is blank in every row and holds only a unit label. | |
sonde_values_nitrate_no3_mg_lNitrate concentration | Nitrate sensor channel; it is blank in every row and holds only a unit label. | |
sonde_values_nitrate_no3_m_vNitrate sensor voltage | Nitrate sensor raw voltage; it is blank in every row and holds only a unit label. | |
sonde_values_odoDissolved oxygen concentration | mg/L | Dissolved oxygen concentration from the optical sensor. |
sonde_values_odo_satDissolved oxygen saturation | % | Dissolved oxygen as a percentage of air saturation. |
sonde_values_orpOxidation-reduction potential | ORP channel; it is blank in every row and holds only a unit label. | |
sonde_values_par_1Light (PAR) sensor 1 | Photosynthetically active radiation channel 1; it is blank in every row and holds only a unit label. | |
sonde_values_par_2Light (PAR) sensor 2 | Photosynthetically active radiation channel 2; it is blank in every row and holds only a unit label. | |
sonde_values_phpH | Acidity of the water on the pH scale. | |
sonde_values_ph_m_vpH sensor voltage | mV | Raw pH probe voltage. |
sonde_values_pressure_absAbsolute pressure | Absolute pressure at the sonde; the unit isn't stated. | |
sonde_values_pressure_gaugeGauge pressure | Gauge pressure channel; it is blank in every row and holds only a unit label. | |
sonde_values_pressure_vert_posVertical position from pressure | m | Vertical position of the sonde derived from pressure. |
sonde_values_rhodamine_ug_lRhodamine concentration | Rhodamine tracer channel; it is blank in every row and holds only a unit label. | |
sonde_values_salinitySalinity | PSU | Salinity of the water, ranging from 0 to about 33. |
sonde_values_sonde_batterySonde battery voltage | V | Internal battery voltage of the sonde. |
sonde_values_sonde_external_voltageSonde external power voltage | V | Voltage of the external power supply to the sonde; 0 when not connected. |
sonde_values_sp_conductivity_usSpecific conductivity | µS/cm | Conductivity standardised to 25 °C. |
sonde_values_tdsTotal dissolved solids | mg/L | Estimated total dissolved solids derived from conductivity. |
sonde_values_turbidityTurbidity | NTU | Water cloudiness measured by the optical turbidity sensor. |
sonde_values_turbidity_tssTurbidity-derived suspended solids | mg/L | Total suspended solids estimated from turbidity; it is 0 in every populated row. |
Data source: Queensland Government