MicroburbsMicroburbs
Free sandbox: try any request below on the sample suburbs, no signup. For every suburb, create an API key.
Classic docs
Microburbs Property Data API
Dataset · Environment

Argyle Square Air Quality Sensor Readings, Carlton

Historical microclimate and air quality readings from sensors in Argyle Square, Carlton (Vic.). Each record is a timestamped reading at a single point, with sound levels, particulate matter (PM1, PM2.5, PM10), gases (carbon monoxide, nitrogen dioxide, ozone), temperature, humidity and device battery and power values. A caller gets 142,507 readings for the suburb or near an address.

Endpoints

Argyle Square Air Quality Sensor Readings, Carlton (map)

GET/v1/suburbs/{suburb_name}/layers/argyle-square-air-quality-sensors-carlton10¢ per call

Served by /v1/suburbs/{suburb_name}/layers/{slug}, which documents every parameter, the response shape and errors, and has a live playground.

Query parameterDescription
fieldsComma-separated field slugs (below). Omit for all.
limitFeatures per page, 1 to 500 (default 200).
offsetItems to skip, for the next page (`next_offset`).
curl -X GET 'https://api.microburbs.com.au/v1/suburbs/Carlton%20%28Vic.%29/layers/argyle-square-air-quality-sensors-carlton' \
  -H 'Authorization: Bearer test'

test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.

Argyle Square Air Quality Sensor Readings, Carlton nearby

GET/v1/properties/{gnaf_id}/layers/argyle-square-air-quality-sensors-carlton/nearby10¢ per call

Served by /v1/properties/{gnaf_id}/layers/{slug}/nearby, which documents every parameter, the response shape and errors, and has a live playground.

Query parameterDescription
radius_mSearch radius in metres, 1 to 2000 (default 500).
fieldsComma-separated field slugs (below). Omit for all.
limitFeatures per page, 1 to 500 (default 200).
offsetItems to skip, for the next page (`next_offset`).
curl -X GET 'https://api.microburbs.com.au/v1/properties/GAVIC721373019/layers/argyle-square-air-quality-sensors-carlton/nearby' \
  -H 'Authorization: Bearer test'

test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.

About this dataset

One location in Argyle Square, Carlton (Vic.), at about 144.9656 E, 37.8028 S. The time field in the sample runs from 1708955630 to 1719203011 (Unix seconds, roughly late February to late June 2024). The dataset description gives a start date of June 2020. Two or more sensors are named, such as Air Quality Sensor 1 and Air Quality Sensor 2. Current to 2026-10-01; refreshed One-off historical series; not updated on a regular schedule.

What it is

A series of readings taken by environmental sensors installed in Argyle Square during a pilot. Each row is one reading from one device, with air quality, noise, weather and device status values. All rows sit at the same point location.

What it shows

It shows how air quality, noise, temperature and humidity changed through the day in one inner-city park. The readings cover particulate matter, carbon monoxide, nitrogen dioxide and ozone, plus average and peak sound pressure levels.

Why use it

Analysts can use it to study short-term microclimate variation, compare pollutant and noise levels across times of day, or test sensor performance. It is a small-area reference for the environment around Carlton's Argyle Square. It is not a basis for suburb-wide conclusions.

How it is built

We hold the sensor readings as point features with the reading attributes attached. They are served as GeoJSON per suburb and for points near an address. All 142,507 rows share a single location, so spatial variation within the square cannot be seen. The source notes that some intervals have no reading for a value, and about 3% of values are missing in each measurement field.

Shortcomings

  • The gas fields (carbon monoxide, nitrogen dioxide, ozone) contain many negative values, such as carbon monoxide down to -5606. These are probably raw or uncalibrated sensor outputs, not concentrations in standard units. Do not compare them with air quality standards without calibration.
  • Coverage is a single park over a limited pilot period. It does not represent air quality across Carlton or Melbourne.
  • About 3% of values are missing in each measurement field, and the source warns that some intervals have no readings. Time series will have gaps.
  • Units are not stated in the source. The units given here are inferred from the field names and value ranges, so confirm them before relying on them. Several fields (particulate sensor error and version, battery and panel values) are device diagnostics, not environmental measures.

Fields

FieldUnitDescription
time
Reading time
seconds (Unix time)Time of the reading as a Unix timestamp in seconds.
dev_id
Device ID
Identifier of the sensor device that made the reading.
sensor_name
Sensor name
Descriptive name of the sensor, such as Air Quality Sensor 1.
averagespl
Average sound pressure level
dBAverage sound pressure level over the reading interval.
carbonmonoxide
Carbon monoxide
Carbon monoxide sensor value, which includes negative values and appears to be uncalibrated.
humidity
Relative humidity
%Relative humidity of the air at the sensor.
ibatt
Internal battery current
Internal battery measure reported by the device, which includes negative values.
nitrogendioxide
Nitrogen dioxide
Nitrogen dioxide (NO₂) sensor value, which includes negative values and appears to be uncalibrated.
ozone
Ozone
Ozone (O₃) sensor value, which includes negative values and appears to be uncalibrated.
particulateserr
Particulate sensor error
Error code of the particulate sensor. It is 0 in all rows.
particulatesvsn
Particulate sensor version
Version code of the particulate sensor, with values of 0 or 151.
peakspl
Peak sound pressure level
dBHighest sound pressure level recorded in the reading interval.
pm1
Particulate matter PM1.0
µg/m³Concentration of particles of 1.0 micrometres or smaller.
pm10
Particulate matter PM10
µg/m³Concentration of particles of 10 micrometres or smaller.
pm25
Particulate matter PM2.5
µg/m³Concentration of particles of 2.5 micrometres or smaller.
temperature
Air temperature
°CAir temperature measured at the sensor.
vbatt
Battery voltage
VBattery voltage of the device.
vpanel
Solar panel voltage
VVoltage of the device's power panel.