Argyle Square Air Quality Sensor Readings, Carlton
Historical microclimate and air quality readings from sensors in Argyle Square, Carlton (Vic.). Each record is a timestamped reading at a single point, with sound levels, particulate matter (PM1, PM2.5, PM10), gases (carbon monoxide, nitrogen dioxide, ozone), temperature, humidity and device battery and power values. A caller gets 142,507 readings for the suburb or near an address.
Endpoints
Argyle Square Air Quality Sensor Readings, Carlton (map)
/v1/suburbs/{suburb_name}/layers/argyle-square-air-quality-sensors-carlton10¢ per callServed by /v1/suburbs/{suburb_name}/layers/{slug}, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/suburbs/Carlton%20%28Vic.%29/layers/argyle-square-air-quality-sensors-carlton' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
Argyle Square Air Quality Sensor Readings, Carlton nearby
/v1/properties/{gnaf_id}/layers/argyle-square-air-quality-sensors-carlton/nearby10¢ per callServed by /v1/properties/{gnaf_id}/layers/{slug}/nearby, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
radius_m | Search radius in metres, 1 to 2000 (default 500). |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/properties/GAVIC721373019/layers/argyle-square-air-quality-sensors-carlton/nearby' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
One location in Argyle Square, Carlton (Vic.), at about 144.9656 E, 37.8028 S. The time field in the sample runs from 1708955630 to 1719203011 (Unix seconds, roughly late February to late June 2024). The dataset description gives a start date of June 2020. Two or more sensors are named, such as Air Quality Sensor 1 and Air Quality Sensor 2. Current to 2026-10-01; refreshed One-off historical series; not updated on a regular schedule.
What it is
A series of readings taken by environmental sensors installed in Argyle Square during a pilot. Each row is one reading from one device, with air quality, noise, weather and device status values. All rows sit at the same point location.
What it shows
It shows how air quality, noise, temperature and humidity changed through the day in one inner-city park. The readings cover particulate matter, carbon monoxide, nitrogen dioxide and ozone, plus average and peak sound pressure levels.
Why use it
Analysts can use it to study short-term microclimate variation, compare pollutant and noise levels across times of day, or test sensor performance. It is a small-area reference for the environment around Carlton's Argyle Square. It is not a basis for suburb-wide conclusions.
How it is built
We hold the sensor readings as point features with the reading attributes attached. They are served as GeoJSON per suburb and for points near an address. All 142,507 rows share a single location, so spatial variation within the square cannot be seen. The source notes that some intervals have no reading for a value, and about 3% of values are missing in each measurement field.
Shortcomings
- The gas fields (carbon monoxide, nitrogen dioxide, ozone) contain many negative values, such as carbon monoxide down to -5606. These are probably raw or uncalibrated sensor outputs, not concentrations in standard units. Do not compare them with air quality standards without calibration.
- Coverage is a single park over a limited pilot period. It does not represent air quality across Carlton or Melbourne.
- About 3% of values are missing in each measurement field, and the source warns that some intervals have no readings. Time series will have gaps.
- Units are not stated in the source. The units given here are inferred from the field names and value ranges, so confirm them before relying on them. Several fields (particulate sensor error and version, battery and panel values) are device diagnostics, not environmental measures.
Fields
| Field | Unit | Description |
|---|---|---|
timeReading time | seconds (Unix time) | Time of the reading as a Unix timestamp in seconds. |
dev_idDevice ID | Identifier of the sensor device that made the reading. | |
sensor_nameSensor name | Descriptive name of the sensor, such as Air Quality Sensor 1. | |
averagesplAverage sound pressure level | dB | Average sound pressure level over the reading interval. |
carbonmonoxideCarbon monoxide | Carbon monoxide sensor value, which includes negative values and appears to be uncalibrated. | |
humidityRelative humidity | % | Relative humidity of the air at the sensor. |
ibattInternal battery current | Internal battery measure reported by the device, which includes negative values. | |
nitrogendioxideNitrogen dioxide | Nitrogen dioxide (NO₂) sensor value, which includes negative values and appears to be uncalibrated. | |
ozoneOzone | Ozone (O₃) sensor value, which includes negative values and appears to be uncalibrated. | |
particulateserrParticulate sensor error | Error code of the particulate sensor. It is 0 in all rows. | |
particulatesvsnParticulate sensor version | Version code of the particulate sensor, with values of 0 or 151. | |
peaksplPeak sound pressure level | dB | Highest sound pressure level recorded in the reading interval. |
pm1Particulate matter PM1.0 | µg/m³ | Concentration of particles of 1.0 micrometres or smaller. |
pm10Particulate matter PM10 | µg/m³ | Concentration of particles of 10 micrometres or smaller. |
pm25Particulate matter PM2.5 | µg/m³ | Concentration of particles of 2.5 micrometres or smaller. |
temperatureAir temperature | °C | Air temperature measured at the sensor. |
vbattBattery voltage | V | Battery voltage of the device. |
vpanelSolar panel voltage | V | Voltage of the device's power panel. |