Abandoned Water Mains - Bundaberg
Line features showing 399 water pipes that have been abandoned (taken out of service) in the Bundaberg area of Queensland. Each feature carries asset ID, pipe diameter, material, class, sub-type and depth where recorded. Available as GeoJSON per suburb or near an address.
Endpoints
Abandoned Water Mains - Bundaberg (map)
/v1/suburbs/{suburb_name}/layers/abandoned-water-mains-bundaberg10¢ per callServed by /v1/suburbs/{suburb_name}/layers/{slug}, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/suburbs/Bundaberg%20South/layers/abandoned-water-mains-bundaberg' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
Abandoned Water Mains - Bundaberg nearby
/v1/properties/{gnaf_id}/layers/abandoned-water-mains-bundaberg/nearby10¢ per callServed by /v1/properties/{gnaf_id}/layers/{slug}/nearby, which documents every parameter, the response shape and errors, and has a live playground.
| Query parameter | Description |
|---|---|
radius_m | Search radius in metres, 1 to 2000 (default 500). |
fields | Comma-separated field slugs (below). Omit for all. |
limit | Features per page, 1 to 500 (default 200). |
offset | Items to skip, for the next page (`next_offset`). |
curl -X GET 'https://api.microburbs.com.au/v1/properties/GAQLD155665863/layers/abandoned-water-mains-bundaberg/nearby' \
-H 'Authorization: Bearer test'test is the public sandbox key: it works only for the sandbox's allowlisted suburbs and addresses. Use your own key for anything else.
About this dataset
Bundaberg region, Queensland, including suburbs such as Alloway, Avenell Heights, Avoca (Qld), Bargara, Branyan, Bundaberg Central, Bundaberg East, Bundaberg North, Bundaberg South and Bundaberg West. The layer has 399 line features within a bounding box of about 151.95 to 152.55 E and -25.24 to -24.72 S. Records start from 6 August 2025. Current to 2026-06-27; refreshed As published; no regular update schedule is stated..
What it is
A map layer of abandoned water mains, drawn as lines. Each line is one pipe segment no longer in service, with attributes such as diameter, material and pipe type.
What it shows
It shows where disused water pipes remain in the ground around Bundaberg, and what they are: potable reticulation, distribution, service or raw bore transfer pipes. Diameters range from 32 to 300, and materials include AC and uPVC.
Why use it
Abandoned pipes matter for excavation, subdivision and construction planning, because old asbestos cement (AC) pipes can be a handling risk and unmapped assets cause delays. They also help in due-diligence checks before dig work on a site.
How it is built
We load the pipe line geometries and their attributes as supplied, then serve them as GeoJSON by suburb and by proximity to an address. All 399 features fall within a suburb boundary. Many attribute fields are blank, and we do not fill them in.
Shortcomings
- Pipe diameter is blank for 25% of rows and material for 26%, so filtering on either drops many pipes.
- Pipe class is blank for 81% of rows and depth for 85%, so depth is not reliable for dig planning.
- Some values are placeholders such as Unknown or TBA, and material codes vary in case (for example uPVC and UPVC).
- The layer lists abandoned pipes only. It is not a full water network, and positions may not be survey-accurate.
Fields
| Field | Unit | Description |
|---|---|---|
asset_idAsset ID | Asset reference for the pipe, in a form like WP.tba0056; blank for about 1% of rows. | |
pipe_diamePipe diameter | mm | Nominal pipe diameter, ranging from 32 to 300; the unit is assumed to be millimetres and is blank for 25% of rows. |
pipe_materPipe material | Material code such as AC or uPVC, sometimes TBA; blank for 26% of rows. | |
pipe_classPipe class | Pressure or strength class of the pipe, for example PN12.5 or CL4; blank for 81% of rows and sometimes Unknown. | |
pipe_sub_tyPipe sub-type | Function of the pipe, such as Water Reticulation Pipe Potable, Water Distribution Pipe Potable, Water Service or Water Transfer Pipe Raw Bore. | |
pipe_depthPipe depth | Recorded depth of the pipe, stored as text (for example 0.8 or 1) or Unknown; blank for 85% of rows, and the unit is assumed to be metres. | |
utilityUtility type | Utility the asset belongs to; the value is Water for every row. |